Dresden | Treatment of exhaust air from a sewage pumping station

Hybrid filter module system eco 1000-ERM
Service Provider
Project
Location of performance / Site: Dresden, Saxony, Germany, Europe
Period: Jul - Nov 2018
Description

Task:

  • Exhaust air treatment at a sewage pumping station

Solution:

  • Hybrid filter module system  eco 1000-ERM
  • with integrated semi-radial tube fan
  • 0.5 m³ UgnCleanPellets® S 1.0
aus industriellen Prozessen und abwassertechnischen Anlagen
Schadstoffabbau: Organische Kohlenwasserstoffe (VOC), Schwefelwasserstoff (H2S)
Volumenstrom: 50
Filtermaterial: UgnCleanPellets® S 1.0