Location of performance / Site: | Achim, Lower Saxony, Germany, Europe |
---|---|
Date: | 2017 |
Task:
Pollutants removed:
UGN® technology employed:
Project description:
The pumping station is an underground structure with a free wastewater infeed of about 2500 m³ per day. Due to turbulence in the infeed flow, odorous substances such as hydrogen sulphide are released from the wastewater, causing odour-related nuisance and biogenic corrosion at the structure. The UGN module was installed to prevent odour-related nuisance. The exhaust air is extracted from the system by way of a fan, and purified. In doing this, diffuse emissions from the pumping station are largely eliminated.
Schadstoffabbau: | Schwefelwasserstoff (H2S) |
---|---|
Volumenstrom: | 150 |
Schadstoffkonzentration im Mittel: | 50 |
Anwendungsbereich: | Abluft aus abwassertechnischen Anlagen |
Filtermaterial: | UgnCleanPellets® S 1.0 |